{"id":5114,"date":"2026-09-24T01:12:22","date_gmt":"2026-09-23T23:12:22","guid":{"rendered":"https:\/\/novogin.com\/?p=5114"},"modified":"2026-09-24T01:12:22","modified_gmt":"2026-09-23T23:12:22","slug":"identiteit-zuiverheid-gemeten-inhoud","status":"publish","type":"post","link":"https:\/\/novogin.com\/en\/identiteit-zuiverheid-gemeten-inhoud\/","title":{"rendered":"Identity, purity and measured content: three different results"},"content":{"rendered":"<p>An analytical report can answer three different questions: <strong>which substance was tested, which other measurable components are present, and how much of the target substance was measured?<\/strong> Identity, purity and measured content are therefore separate results. A favourable result for one does not replace the other two.<\/p>\n<h2>Three questions side by side<\/h2>\n<h3 id=\"identiteit\">Identity<\/h3>\n<p><strong>Question:<\/strong> Does the sample match the stated substance? A report may support this through comparison with a reference or an appropriate mass or spectral result. This does not automatically establish how much of the substance is present or which impurities are absent.<\/p>\n<h3 id=\"chromatografische-zuiverheid\">Chromatographic purity<\/h3>\n<p><strong>Question:<\/strong> How do the assigned peaks compare within this method? A report may, for example, show a percentage of integrated peak areas. This is not automatically the mass percentage of the entire vial or the measured quantity.<\/p>\n<h3 id=\"gemeten-inhoud\">Measured content<\/h3>\n<p><strong>Question:<\/strong> How much of the target substance was determined on the reported basis? A report may, for example, state mg per tested sample or per vial. This does not automatically establish identity or the absence of all possible contaminants.<\/p>\n<p>This overview is a reading guide, not a standard for every report. The precise meaning depends on the method, detector, calculation, unit and sample description. ICH Q2(R2) distinguishes identification, impurities\/purity and assay or content as different objectives of analytical procedures. That guideline describes pharmaceutical methods; here we use only the general analytical distinction, without suggesting that Novogin materials fall under that framework.<\/p>\n<h2>Identity: which substance was tested?<\/h2>\n<p>In an identity test, a laboratory compares a property of the sample with what is expected for the target substance. Which property is convincing depends on the procedure and on substances that may resemble it. ICH Q2(R2) addresses selectivity: a method must adequately distinguish the intended substance from potential interferences. Sometimes two complementary procedures are needed.<\/p>\n<p>An LC-MS result can, for example, add mass information to chromatographic separation. A measured mass that matches expectations supports identification. Its scope depends on the instrument settings and the interpretation actually performed. The abbreviation LC-MS in a report does not by itself prove that the full molecular structure or amino acid sequence was established. The <a href=\"\/en\/hplc-en-lc-ms\/\">guide to HPLC and LC-MS<\/a> explains the information these methods generally provide.<\/p>\n<p>A product name at the top of a document is not an analytical identification either. Look for the test, result, conclusion and linkage to the tested sample.<\/p>\n<h2>Purity: what was counted in this measurement?<\/h2>\n<p>A chromatographic purity percentage can be calculated from the area of an assigned main peak relative to the area of the included peaks. Agilent explains that <strong>area%<\/strong> compares peak areas within the measured signal without prior calibration. For a direct comparison of quantities, this approach assumes, among other things, that components produce comparable detector responses. This is not necessarily the case.<\/p>\n<p>Another component may also leave the column together with the main peak. Two substances then appear as a single peak in one detector trace. A purity percentage must therefore be read alongside the method, detector, wavelength or measurement mode, the definition of the included peaks and the quality of the separation. <a href=\"\/en\/hoe-leest-u-een-chromatogram\/\">Reading a chromatogram<\/a> requires more than identifying the tallest peak.<\/p>\n<p>For peptides, Sigma-Aldrich also distinguishes between chromatographic purity and peptide content. A value such as 99% on a chromatogram therefore does not establish that 99% of the total vial mass consists of the target peptide. Components that the procedure does not measure are not automatically included in that percentage.<\/p>\n<h2>Measured content: how much target substance does the laboratory report?<\/h2>\n<p>A content determination gives a quantity or concentration on a clearly defined basis. Check whether the report refers to the submitted sample, a calculation per vial, a solution or another unit. The nominal quantity on a label is a product specification; the measured quantity is an analytical result. They can only be meaningfully compared when the samples and units correspond.<\/p>\n<p>A quantitative determination requires an appropriate method and evidence of measurement performance. ICH Q2(R2) discusses, among other things, range, accuracy and precision for quantitative procedures. A standalone chromatogram image or the name of an instrument does not provide a reported quantity. Look for a number with a unit, the substance concerned, the sample basis and any explanation of the calculation.<\/p>\n<p>If a report states an uncertainty or acceptance limit, include it in your interpretation. Measurement values are not exact, context-free numbers. Eurachem describes how uncertainty arising from the method and measurement is assessed. If this information is missing from a public report, ask what the result means when a difference matters to your research decision.<\/p>\n<h2>Read the results as one set of evidence<\/h2>\n<p>Start with the <a href=\"\/en\/hoe-leest-u-een-coa\/\">COA and sample information<\/a>: which product, form, batch number and sample ID are stated? Then check <a href=\"\/en\/analyserapport-actuele-batch-controleren\/\">whether the report matches the current batch<\/a>. Next, establish which question each test addressed. Only draw a conclusion when the corresponding result, unit and procedure support it.<\/p>\n<p>A hypothetical report showing a matching mass, 99 area% and a nominal quantity of 10 mg does not yet establish a measured content of 10 mg. Nor does the percentage indicate properties for which no test is included. The three pieces of information complement each other, but remain distinct.<\/p>\n<p>In the <a href=\"\/en\/coas\/\">Novogin COA library<\/a> you can view available batch documentation for a product. This guide does not assess a specific batch. Always check the original report and its linkage to the material offered or received.<\/p>\n<h2>Sources<\/h2>\n<ol>\n<li><a href=\"https:\/\/www.ema.europa.eu\/en\/ich-q2r2-validation-analytical-procedures-scientific-guideline\" target=\"_blank\" rel=\"noopener\">EMA \/ ICH Q2(R2), Validation of analytical procedures<\/a> \u2014 distinction between identification, impurities and quantitative content; method performance.<\/li>\n<li><a href=\"https:\/\/openlab.help.agilent.com\/2.7\/en\/mergedProjects\/DataAnalysis\/3405000203.htm\" target=\"_blank\" rel=\"noopener\">Agilent OpenLab, Area% and height%<\/a> \u2014 calculation and assumptions behind peak area percentages.<\/li>\n<li><a href=\"https:\/\/www.sigmaaldrich.com\/DE\/en\/technical-documents\/technical-article\/protein-biology\/protein-quantitation\/explanation-of-peptide\" target=\"_blank\" rel=\"noopener\">Sigma-Aldrich, Explanation of peptide content and purity<\/a> \u2014 distinction between peptide purity and peptide content.<\/li>\n<li><a href=\"https:\/\/www.waters.com\/nextgen\/pt\/pt\/library\/application-notes\/2017\/lc-uv-ms-based-synthetic-peptide-identification-and-impurity-profiling.html\" target=\"_blank\" rel=\"noopener\">Waters, LC-UV-MS peptide identification and impurity profiling<\/a> \u2014 complementary detection in peptide analysis.<\/li>\n<li><a href=\"https:\/\/www.eurachem.org\/index.php\/publications\/guides\/quam\" target=\"_blank\" rel=\"noopener\">Eurachem\/CITAC, Quantifying Uncertainty in Analytical Measurement<\/a> \u2014 interpretation of measurement uncertainty.<\/li>\n<\/ol>\n<p>This knowledge base covers analytical documentation for professional laboratory research. It does not provide advice on use in humans or animals.<\/p>","protected":false},"excerpt":{"rendered":"<p>What do identity, chromatographic purity and measured content mean individually? Read what each result does and does not substantiate.<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[45],"tags":[],"class_list":["post-5114","post","type-post","status-publish","format-standard","hentry","category-kennisbank"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"_links":{"self":[{"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/posts\/5114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/comments?post=5114"}],"version-history":[{"count":3,"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/posts\/5114\/revisions"}],"predecessor-version":[{"id":5123,"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/posts\/5114\/revisions\/5123"}],"wp:attachment":[{"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/media?parent=5114"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/categories?post=5114"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/novogin.com\/en\/wp-json\/wp\/v2\/tags?post=5114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}